FT50-98

  • Beschreibung

Preis- und Lieferzeit auf Anfrage

 

MATERIAL 98 (Permeabilität 10.000)

 

98-Material ist ein Material mit hoher Permeabilität, das für EMI / RMI-Unterdrückung, Gleichtaktdrosseln, Impuls- und Breitbandtransformatoren verwendet wird.

Electrical Specifications FT50-98

Item

Unit/Symbol

Condition

Value

Tol.

Freq. MHz Resonanz

Freq. MHz

Breit-band

Freq.

MHz Drossel

AL-

mH/1000

@ 5 gauss in a de-gaussed state

5430

±30%

1-250 kHz

2 kHz -

2 MHz

100 kHz-

1 MHz

le

cm

N/A

2.95

(29.5)

±10%

Saturation Flux Density (4,700 G at 15 Oe, 25°C)

470 mT, 11.9 A•T/cm

 

Effective Path Length

Ae

cm²

N/A

0.126

(12.9)

±10%

Curie Temperature

210°C

 

Effective Cross-Sectional

Ve

cm³

N/A

0.373

(381)

±10%

Maximum Usable Frequency (50% roll-off) 

≤1.5 MHz 

 

Effective Core Volume

Density

g/cm³

N/A

4.8

Typ.

Remanence (1,500 G, 25°C)  

150 mT

Permeability

µi

Typical

10.000

±20%

Coercivity

Oe, A/m

Typical

0.04, 3

Typ.

Flux Density

Gauss, B

Typical

4300

Typ.

Resistivity

5 Ω-m

 

Gauss, H

@ 1194 A/m, 15 oe mT

430

Typ.

Curie temperature

°C

Tc

> 125

Typ.

Density 

4.8 g/cm

WaAc

0.05

Resistivity

Ω cm p

Typical

0.15

Typ.

Relative Loss Factor

10 -6
<!--[if !supportLineBreakNewLine]-->
<!--[endif]-->

Tan δ/ µi

˂7

Typ.

kHz

@ Frequency

10

Typ.

Max. Usable freq.

MHz

(50% roll-off) 

˂0.25

Typ.

Remanence

G, mT

Typical

800, 80

Typ.

Disaccommodation Factor

10 -6

Typical

˂3

Typ.

Condition

 

25°C

 

@60°C

 

@100°C

@120°C

I

25 kHz

N/A

200 mT

N/A

2000 G

N/A

N/A

II

100 kHz

N/A

100 mT

N/A

1000 G

N/A

N/A

III

500 kHz

N/A

50 mT

N/A

500 G

N/A

N/A

IV

700 kHz

N/A

50 mT

N/A

500 G

N/A

N/A

Case

In

Toleranz

mm

Toleranz

Weight

Gewicht

B (Outer Diameter)/mm

0.500

0.510 Max

12.7

12.96 Max

1.90 g

1.90 g

A (Inner Diameter)/mm

0.281

0.271 Min

7.14

6.88 Min

---

---

H (Height)/mm

0.188

0.193 Max

4.78

4.91 Max

---

--

INDUCTANCE

 

AL-value (nH/T²)

 

Test conditions

5430 ± 30%

10 kHz

0.5 mT (For N = 5, use 0.139 mA), 25°C

ELECTRICAL LOSSES

Tan δ/ µi

 

Production lot limit Average

 

Test conditions

 

≤3.5·10 -6

 

≤3·10 -6

 

10 kHz

0.5 mT, 25ºC

 

≤55·10 -6

 

 

≤45·10 -6

 

 

100 kHz