ft23-61

FT50 A-FC

  • Beschreibung

Preis- und Lieferzeit auf Anfrage

MATERIAL A – FC  (Permeabilität 3000)

Große Sättigungsflussdichte bei hoher Temperatur. Für Transformatoren und Filter zwischen 0,5 und 50 MHz.

F-Material ist ein Allzweck-Leistungstransformator, Induktor und Filtermaterial für mittlere Frequenzen. Etwas länger in Perm als P oder R-Material. Entwickelt für geringste Verluste bei 60 ° C.

F material is a medium frequency general-purpose power transformer, inductor and filter material. Slightly higher in perm than P or R Material. Engineered for lowest losses at 60°C.

Electrical Specifications FT50 A-FC

Item

Unit/Symbol

Condition

Value

Tol.

Freq. MHz Resonanz

Freq. MHz

Breit-band

Freq.

MHz Drossel

AL-

mH/1000

@ 5 gauss in a de-gaussed state

1782

±20%

0.001-1

0.5-30

1.0-20

le

cm

N/A

3.12

(31.7)

±10%

Saturation Flux Density (4,700 G at 15 Oe, 25°C)

470 mT, 11.9 A•T/cm

 

Effective Path Length

Ae

cm²

N/A

0.146

(14.2)

±10%

Curie Temperature

210°C

 

Effective Cross-Sectional

Ve

cm³

N/A

0.457

(451.7)

±10%

Maximum Usable Frequency (50% roll-off) 

≤1.5 MHz 

 

Effective Core Volume

Density

g/cm³

N/A

4.8

Typ.

Remanence (1,500 G, 25°C)  

150 mT

Permeability

µi

Typical

3000

±20%

Coercivity

Oe, A/m

Typical

0.2, 16

Typ.

Flux Density

Gauss, B

Typical

4900

Typ.

Resistivity

5 Ω-m

 

Gauss, H

@ 1194 A/m, 15 oe mT

490

Typ.

Curie temperature

°C

Tc

> 250

Typ.

Density 

4.8 g/cm

 

Resistivity

Ω cm p

Typical

2

Typ.

 

Relative Loss Factor

10 -6

Tan δ/ µi

˂8

Typ.

kHz

@ Frequency

100

Typ.

Max. Usable freq.

MHz

(50% roll-off) 

˂1.3

Typ.

Remanence

G, mT

Typical

1200, 120

Typ.

Disaccommodation Factor

10 -6

Typical

N/A

Typ.

Condition

 

25°C

 

@60°C

 

@100°C

@120°C

I

25 kHz

90

200 mT

160

2000 G

240

N/A

II

100 kHz

100

100 mT

180

1000 G

225

N/A

III

500 kHz

N/A

50 mT

N/A

500 G

N/A

N/A

IV

700 kHz

N/A

50 mT

N/A

500 G

N/A

N/A

Case

In

Toleranz

mm

Toleranz

Weight

Gewicht

AL value (nH/T²)

Test conditions

1782± 20%

10 kHz, 0.5 mT (For N = 5, use 0.5 mA), 25°C

CORE LOSSES

PLmax

Production lot limit

Max avg

Test conditions

99.2 mW

(220 mW/cm³)

 

90.2 mW

(200 mW/cm³)

 

25 kHz, 200 mT, 100°C

B (Outer Diameter)/mm

0.500

0.525 Max

12.7

13.34 Max

2.04 g

1.90 g

A (Inner Diameter)/mm

0.312

0.287 Min

8.14

8.49 Min

---

---

H (Height)/mm

0.250

0.272 Max

6.35

6.91 Max

---

--

Epoxy rated for 200°C continuous operation.

Epoxy für den Dauerbetrieb bei 200 ° C ausgelegt.

Voltage breakdown rating 1500 V Min Wire-to-Wire.

Spannungsabbauwert 1500 V Min. Draht-zu-Draht.